Thien Son Technology Corporation - Nhà cung cấp thiết bị điện-tự động hàng đầu tại Việt Nam

LÕI CHỐNG SÉT LAN TRUYỀN – TYPE 2 SURGE PROTECTION PLUG – VAL-MS 230 ST – 2798844

Surge protection connector type 2 with high-capacity varistor for VAL-MS base element, thermal monitoring, visual fault warning. Design: 230 V AC

 

VAL-MS 230 ST – 2798844 là lõi chống sét 40kA giữa dây L-N cho các dòng chống sét 1 pha và 3 pha VAL-MS 230/1+1 hoặc VAL-MS 230/3+1 của Phoenix Contact

 

Dimensions

Height 52.4 mm
Width 17.5 mm
Depth 55.3 mm
Horizontal pitch 1 Div.

Back to top

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -40 °C … 80 °C
Ambient temperature (storage/transport) -40 °C … 80 °C
Altitude ≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation) 5 % … 95 %
Shock (operation) 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation) 5g (10 … 500 Hz / 2.5 h / X, Y, Z)

Back to top

General

IEC test classification II
T2
EN type T2
IEC power supply system TN
TT
Mode of protection L-N
L-PEN
Mounting type on base element
Color jet black RAL 9005
Housing material PA 6.6
Degree of pollution 2
Flammability rating according to UL 94 V-0
Type DIN rail module, two-section, divisible
Number of positions 1
Arrester can be tested with CHECKMASTER from software version: From SW rev. 1.10
Surge protection fault message optical

Back to top

Protective circuit

Nominal voltage UN 240/415 V AC (TN)
240/415 V AC (TT)
Nominal frequency fN 50 Hz (60 Hz)
Maximum continuous voltage UC 275 V AC
Residual current IPE ≤ 0.45 mA
Standby power consumption PC ≤ 120 mVA
Nominal discharge current In (8/20) µs 20 kA
Maximum discharge current Imax (8/20) µs 40 kA
Short-circuit current rating ISCCR 25 kA
Voltage protection level Up ≤ 1.35 kV
Residual voltage Ures ≤ 1.35 kV (at In)
≤ 1.1 kV (at 10 kA)
≤ 1 kV (at 5 kA)
≤ 0.9 kV (at 3 kA)
TOV behavior at UT 335 V AC (5 s / withstand mode)
440 V AC (120 min / safe failure mode)
Response time tA ≤ 25 ns
Max. backup fuse with branch wiring 125 A (gG)

Back to top

Connection data

Connection method pluggable

Back to top

UL specifications

SPD Type 4CA
Maximum continuous operating voltage MCOV (L-N) 275 V AC
Nom. voltage 230 V AC
Mode of protection L-N
Power distribution system Single phase
Nominal frequency 50/60 Hz
Measured limiting voltage MLV (L-N) 1910 V
Nominal discharge current In (L-N) 20 kA

Back to top

Standards and Regulations

Standards/regulations IEC 61643-11 2011
EN 61643-11 2012

Back to top

Environmental Product Compliance

China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration”

Back to top

Classifications

eCl@ss

eCl@ss 10.0.1 27130890
eCl@ss 4.0 27130800
eCl@ss 4.1 27130800
eCl@ss 5.0 27130800
eCl@ss 5.1 27130800
eCl@ss 6.0 27130800
eCl@ss 7.0 27130805
eCl@ss 8.0 27130890
eCl@ss 9.0 27130890

Back to top

ETIM

ETIM 2.0 EC000941
ETIM 3.0 EC000941
ETIM 4.0 EC000941
ETIM 5.0 EC002496
ETIM 6.0 EC000941
ETIM 7.0 EC000941

Back to top

UNSPSC

UNSPSC 6.01 30212010
UNSPSC 7.0901 39121610
UNSPSC 11 39121610
UNSPSC 12.01 39121610
UNSPSC 13.2 39121620
UNSPSC 18.0 39121620
UNSPSC 19.0 39121620
UNSPSC 20.0 39121620
UNSPSC 21.0 39121620

 

 

There are no reviews yet.

Be the first to review “LÕI CHỐNG SÉT LAN TRUYỀN – TYPE 2 SURGE PROTECTION PLUG – VAL-MS 230 ST – 2798844”

Your email address will not be published. Required fields are marked *

Updating…
  • No products in the cart.